How can we help you?
imageimageimageimageimage
Click to enlarge
preview
preview
preview
preview
preview
Back to the product list

Air-Z Flex
Air Displacement Pumps

  • Automated air displacement pipettor module with high resolution encoder for dependable step loss detection
  • Horizontal and vertical mounting configurations
  • Compact design
  • Available in 50 µL, 250 µL, and 1000 µL volumes
  • Optional pressure sensor and control electronics
  • Prevention of cross contamination and carryover during sample transfer and reagent aliquoting
  • No tubing and priming required
  • Custom tip adaptors, orientations and sizes to fit your instrument design
  • Optional tip adaptor and disposable tips

Air-Z Flex

Automated air displacement pipetting module available with or without control electronics and pressure sensor.

air-z-flex-pump-min.png

Air-Z Legacy

TriContinent's first air displacement pipette with proven technology for use on liquid handling robotic systems.

z_pump_460.gif

Air-Z Mini

Most economical model for low-duty cycle applications, designed for easy installation and replacement.

air-z_mini_1.gif

Air-Z Premier

Fully-featured, fully programmable air-displacement pipetting module with integrated tip ejection and automatic detection of liquid levels, tips, tip blockage, step loss and more.

air-z_premier_1.png

*Parameters without full electronics dependent on customer use

air-z_flex_drawings_1.png

air-z_flex_drawings_2.png

Z-Series Warranty Information

TriContinent operates an ISO 13485 registered manufacturing facility that delivers the highest quality products. Z-Series Pumps are general laboratory components not subject to FDA regulatory approval. TriContinent uses the highest quality components with applicable safety markings to meet the needs of system designers. Z-Series Pumps do not carry independent CE markings as they are components designed for use within larger systems which are subject to independent testing and certification.

We stand behind the Z-Series Pumps with a 1-year warranty. During the warranty period, should a Z-Series Pump fail, call us with an explanation of malfunction and TriContinent will issue a Return Material Authorization (RMA) number for repair or replacement at our discretion, at no charge.

It is the responsibility of the customer to determine the suitability of an application and the material compatibility of our product with your application.

When returning a product for repair or replacement, please contact TriContinent Customer Service to receive an RMA number. When calling please be sure to have the following information available:

  • Catalog Number
  • Serial Number
  • Explanation of Malfunction

TriContinent will not accept the return of any product with out prior approval. TriContinent reserves the right to refuse a return of product that has been used with infectious microbiological or radioactive substances or any other materials that may be deemed hazardous.

The RMA number should be referenced on the outside of the shipping container when returning to TriContinent.

Warranty Exlusions

The above warranty shally not apply for defective products resulting from:

  • Improper or Inadquate maintenance by the customer
  • Unauthorized maintenance or service
  • Customer misuse
  • Operation outside of environmental specifications for the product
  • Instruments returned without proper packagings

Note: For equipment damaged in shipping, please contact the shipper directly.

Related TriContinent Products

Compare Air-Z Models

Air-Z Flex

Automated air displacement pipetting module available with or without control electronics and pressure sensor.

air-z-flex-pump-min.png

Air-Z Legacy

TriContinent's first air displacement pipette with proven technology for use on liquid handling robotic systems.

z_pump_460.gif

Air-Z Mini

Most economical model for low-duty cycle applications, designed for easy installation and replacement.

air-z_mini_1.gif

Air-Z Premier

Fully-featured, fully programmable air-displacement pipetting module with integrated tip ejection and automatic detection of liquid levels, tips, tip blockage, step loss and more.

air-z_premier_1.png

Specifications

*Parameters without full electronics dependent on customer use

Dimensions

air-z_flex_drawings_1.png

air-z_flex_drawings_2.png

Warranty

Z-Series Warranty Information

TriContinent operates an ISO 13485 registered manufacturing facility that delivers the highest quality products. Z-Series Pumps are general laboratory components not subject to FDA regulatory approval. TriContinent uses the highest quality components with applicable safety markings to meet the needs of system designers. Z-Series Pumps do not carry independent CE markings as they are components designed for use within larger systems which are subject to independent testing and certification.

We stand behind the Z-Series Pumps with a 1-year warranty. During the warranty period, should a Z-Series Pump fail, call us with an explanation of malfunction and TriContinent will issue a Return Material Authorization (RMA) number for repair or replacement at our discretion, at no charge.

It is the responsibility of the customer to determine the suitability of an application and the material compatibility of our product with your application.

When returning a product for repair or replacement, please contact TriContinent Customer Service to receive an RMA number. When calling please be sure to have the following information available:

  • Catalog Number
  • Serial Number
  • Explanation of Malfunction

TriContinent will not accept the return of any product with out prior approval. TriContinent reserves the right to refuse a return of product that has been used with infectious microbiological or radioactive substances or any other materials that may be deemed hazardous.

The RMA number should be referenced on the outside of the shipping container when returning to TriContinent.

Warranty Exlusions

The above warranty shally not apply for defective products resulting from:

  • Improper or Inadquate maintenance by the customer
  • Unauthorized maintenance or service
  • Customer misuse
  • Operation outside of environmental specifications for the product
  • Instruments returned without proper packagings

Note: For equipment damaged in shipping, please contact the shipper directly.