C-Series Syringe Pumps
Syringe Pump
- Syringe pump module designed for liquid handling in automated instrumentation
- Extremely high dispense precision and accuracy
- 3cm stroke for syringe sizes from 50 μL to 12.5 mL
- Designed for low flow, low pulsation applications
- Different valve options (3, 4 or 6 way) to allow multi-source aspiration and dispensing (e.g. reagents)
- Easy to integrate
- Long life and highly reliable
- Compact design
- Flexible configurations and customizable
Share
Superior Liquid Handling Performance
The TriContinent C-Series Syringe Pump provides extremely high accuracy and precision for low volume dispensing, diluting and pipetting. It is also an ideal solution for applications that require low flow rates and low pulsation as it achieves a resolution of up to 192,000 micro steps/full stroke. Thanks to their compact design and flexible configurations our pumps are used for liquid handling tasks across a wide range of applications such as Diagnostics, Next-Gen Sequencing, Flow-Cytometry, Sample Preparation in general and many more.
Flexible Configuration
TriContinent offers syringe sizes between 50 μL to 12.5 mL and different valve options with 3,4 and 6 way for transferring liquids from and to multiple sources.
In case your instrument requires a customized solution we are also able to accommodate customer specific designs and configurations. Please download our case studies to read more about our cooperation with word-leading OEM customers.
Long-Life
The C-Series syringe pumps are highly robust and reliable as they utilize a proprietary high-efficiency, direct-drive design that does not use belts that can stretch or wear out. The robust drive mechanism has been life-tested and lasts several million cycles with no maintenance required throughout its life.
In addition, our rotary sheer valves showed in lifetime tests up to 24 times the life of competing valves.
Easy To Integrate
Our pumps are programmable and easy to integrate as they use the Cavro® protocol and hence can be used as a seamless replacement for industry standard pumps. They also utilize standard communication protocols and mounting configurations used by other compact syringe pump designs, thereby eliminating expensive and time-consuming re-development.
Competitive Advantages
- A seamless replacement for industry standard pumps using the Cavro® protocol
- High Resolution options available up to 192,000 steps/full-stroke
- Proprietary high-efficiency and maintenance-free drive system
- Direct-drive design (no belts to stretch or break)
- Long-life rotary shear valves (up to 24 times the life of competing valves)
- Syringe sizes from 50 μL to 12.5 mL
C-SERIES PUMP INTERFACE DETAILS
C-SERIES WITH MULTIPORT VALVE INTERFACE DETAILS
ALL MOUNTING HOLES ARE M3 X 0.5mm X 6.3 mm DEEP MINIMUM
ALL DIMENSIONS UNLESS OTHERWISE SPECIFIED ARE .XXX + .008 [.02 mm]
** 6-way distribution valve is only compatible with C3000MP and C24000MP syringe pumps (Cat# 10095 & 10099).
C-Series Warranty Information
TriContinent operates an ISO 13485 registered manufacturing facility that delivers the highest quality products. C-Series Pumps are general laboratory components not subject to FDA regulatory approval. TriContinent uses the highest quality components with applicable safety markings to meet the needs of system designers. C-Series Pumps do not carry independent CE markings as they are components designed for use within larger systems which are subject to independent testing and certification.
We stand behind the C-Series Pumps with a 1-year warranty. During the warranty period, should a C-Series Pump fail, call us with an explanation of malfunction and TriContinent will issue a Return Material Authorization (RMA) number for repair or replacement at our discretion, at no charge.
TriContinent also guarantees its Valves to be free of defects in materials and workmanship for 1-year. Any valve, which fails due to such defects, will be repaired or replaced at our dscretion at no charge provided the device is returned through our RMA process.
It is the responsibility of the customer to determine the suitability of an application and the material compatibility of our product with your application.When returning a product for repair or replacement, please contact TriContinent Customer Service to receive an RMA number. When calling please be sure to have the following information available:
- Catalog Number
- Serial Number
- Explanation of Malfunction
TriContinent will not accept the return of any product with out prior approval. TriContinent reserves the right to refuse a return of product that has been used with infectious microbiological or radioactive substances or any other materials that may be deemed hazardous.
The RMA number should be referenced on the outside of the shipping container when returning to TriContinent.
Warranty Exclusions
The above warranty shall not apply for defective products resulting from:
- Improper or Inadequate maintenance by the customer
- Unauthorized maintenance or service
- Customer misuse
- Operation outside of the environmental specifications for the product
- Instruments returned without proper packaging
There is no warranty expressed for the following products:
- Syringes
- Plungers
Note: For equipment damaged in shipping, please contact the shipper directly.
Related TriContinent Products
SYRINGES
Made from premium borosilicate glass, and has precision bore diameters of +/- 0.0002". Our syringe seal materials include high-quality PTFE, UHMWPE, or custom UHMWPE blends.
Learn More
ROTARY VALVES AND VALVE CONTROLLER
Specifically developed rotary valves to provide unsurpassed life and reliability in instrument applications using syringe pumps.
Learn More
AIR-Z PREMIER
The Air-Z Premier is a full featured, fully programmable positive displacement pipetting module with integrated and disposable tip ejection. The system can pipette from a few microliters of aspirated liquid up to five milliliters with superior precision and accuracy. The Air-Z Premier comes with pressure and capacitive liquid level detection, and clog detection.
Learn More
MC-SERIES
Multi-channel syringe pump designed for multiple probe liquid handling applications.
Learn More
AIR-Z FLEX
The Air-Z Flex is our most flexible automated air displacement pipetting module yet. It is available with or without electronics and a pressure sensor. It provides mounting flexibility with horizontal or vertical configurations. Its compact design requires no tubing or priming. It also comes with an optional tip adaptor and disposable tips.
Learn More
Description
Superior Liquid Handling Performance
The TriContinent C-Series Syringe Pump provides extremely high accuracy and precision for low volume dispensing, diluting and pipetting. It is also an ideal solution for applications that require low flow rates and low pulsation as it achieves a resolution of up to 192,000 micro steps/full stroke. Thanks to their compact design and flexible configurations our pumps are used for liquid handling tasks across a wide range of applications such as Diagnostics, Next-Gen Sequencing, Flow-Cytometry, Sample Preparation in general and many more.
Flexible Configuration
TriContinent offers syringe sizes between 50 μL to 12.5 mL and different valve options with 3,4 and 6 way for transferring liquids from and to multiple sources.
In case your instrument requires a customized solution we are also able to accommodate customer specific designs and configurations. Please download our case studies to read more about our cooperation with word-leading OEM customers.
Long-Life
The C-Series syringe pumps are highly robust and reliable as they utilize a proprietary high-efficiency, direct-drive design that does not use belts that can stretch or wear out. The robust drive mechanism has been life-tested and lasts several million cycles with no maintenance required throughout its life.
In addition, our rotary sheer valves showed in lifetime tests up to 24 times the life of competing valves.
Easy To Integrate
Our pumps are programmable and easy to integrate as they use the Cavro® protocol and hence can be used as a seamless replacement for industry standard pumps. They also utilize standard communication protocols and mounting configurations used by other compact syringe pump designs, thereby eliminating expensive and time-consuming re-development.
Competitive Advantages
- A seamless replacement for industry standard pumps using the Cavro® protocol
- High Resolution options available up to 192,000 steps/full-stroke
- Proprietary high-efficiency and maintenance-free drive system
- Direct-drive design (no belts to stretch or break)
- Long-life rotary shear valves (up to 24 times the life of competing valves)
- Syringe sizes from 50 μL to 12.5 mL
Specifications
Dimensions
C-SERIES PUMP INTERFACE DETAILS
C-SERIES WITH MULTIPORT VALVE INTERFACE DETAILS
ALL MOUNTING HOLES ARE M3 X 0.5mm X 6.3 mm DEEP MINIMUM
ALL DIMENSIONS UNLESS OTHERWISE SPECIFIED ARE .XXX + .008 [.02 mm]
Ordering Information
** 6-way distribution valve is only compatible with C3000MP and C24000MP syringe pumps (Cat# 10095 & 10099).
Downloads
Warranty
C-Series Warranty Information
TriContinent operates an ISO 13485 registered manufacturing facility that delivers the highest quality products. C-Series Pumps are general laboratory components not subject to FDA regulatory approval. TriContinent uses the highest quality components with applicable safety markings to meet the needs of system designers. C-Series Pumps do not carry independent CE markings as they are components designed for use within larger systems which are subject to independent testing and certification.
We stand behind the C-Series Pumps with a 1-year warranty. During the warranty period, should a C-Series Pump fail, call us with an explanation of malfunction and TriContinent will issue a Return Material Authorization (RMA) number for repair or replacement at our discretion, at no charge.
TriContinent also guarantees its Valves to be free of defects in materials and workmanship for 1-year. Any valve, which fails due to such defects, will be repaired or replaced at our dscretion at no charge provided the device is returned through our RMA process.
It is the responsibility of the customer to determine the suitability of an application and the material compatibility of our product with your application.When returning a product for repair or replacement, please contact TriContinent Customer Service to receive an RMA number. When calling please be sure to have the following information available:
- Catalog Number
- Serial Number
- Explanation of Malfunction
TriContinent will not accept the return of any product with out prior approval. TriContinent reserves the right to refuse a return of product that has been used with infectious microbiological or radioactive substances or any other materials that may be deemed hazardous.
The RMA number should be referenced on the outside of the shipping container when returning to TriContinent.
Warranty Exclusions
The above warranty shall not apply for defective products resulting from:
- Improper or Inadequate maintenance by the customer
- Unauthorized maintenance or service
- Customer misuse
- Operation outside of the environmental specifications for the product
- Instruments returned without proper packaging
There is no warranty expressed for the following products:
- Syringes
- Plungers
Note: For equipment damaged in shipping, please contact the shipper directly.
Related Products
Related TriContinent Products
SYRINGES
Made from premium borosilicate glass, and has precision bore diameters of +/- 0.0002". Our syringe seal materials include high-quality PTFE, UHMWPE, or custom UHMWPE blends.
Learn More
ROTARY VALVES AND VALVE CONTROLLER
Specifically developed rotary valves to provide unsurpassed life and reliability in instrument applications using syringe pumps.
Learn More
AIR-Z PREMIER
The Air-Z Premier is a full featured, fully programmable positive displacement pipetting module with integrated and disposable tip ejection. The system can pipette from a few microliters of aspirated liquid up to five milliliters with superior precision and accuracy. The Air-Z Premier comes with pressure and capacitive liquid level detection, and clog detection.
Learn More
MC-SERIES
Multi-channel syringe pump designed for multiple probe liquid handling applications.
Learn More
AIR-Z FLEX
The Air-Z Flex is our most flexible automated air displacement pipetting module yet. It is available with or without electronics and a pressure sensor. It provides mounting flexibility with horizontal or vertical configurations. Its compact design requires no tubing or priming. It also comes with an optional tip adaptor and disposable tips.
Learn More